Ola, boa noite.
Como os HDs neste server são hotplug, basta trocar o HD e monitorar o rebuild através do software da controladora (Array Configuration Utility ou Smart Storage Administrator). Se vc não tiver segue link para download:
Para todas as versões de Windows x64
http://ftp.hp.com/pub/softlib2/software1/sc-windows/p1308213277/v87168/cp020336.exe
Para todas as versões de Windows x86 (32 Bit)
http://ftp.hp.com/pub/softlib2/software1/sc-windows/p640080033/v80009/cp018120.exe
Não é preciso reiniciar o servidor para iniciar o rebuild este processo é automatizado na controladora, quando isso estiver ocorrendo os 2 HDs ficarm com os leds piscando.
Segue combinações:
SAS/SATA hard drive LED combinations:Online/activity LED (green)Fault/UID LED (amber/blue)Interpretation
On, off, or flashing | Alternating amber and blue | The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. |
On, off, or flashing | Steadily blue | The drive is operating normally, and it has been selected by a management application. |
On | Amber, flashing regularly (1 Hz) | A predictive failure alert has been received for this drive. Replace the drive as soon as possible. |
On | Off | The drive is online, but it is not active currently. |
Flashing regularly (1 Hz) | Amber, flashing regularly (1 Hz) | Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. |
Flashing regularly (1 Hz) | Off | Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration. |
Flashing irregularly | Amber, flashing regularly (1 Hz) | The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. |
Flashing irregularly | Off | The drive is active, and it is operating normally. |
Off | Steadily amber | A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. |
Off | Amber, flashing regularly (1 Hz) | A predictive failure alert has been received for this drive. Replace the drive as soon as possible. |
Off | Off | The drive is offline, a spare, or not configured as part of an array. |
Qualquer duvida nos procure e caso ficou tudo OK com as dicas que passei por favor marque este post como solucionado para ajudar nossos futuros colegas.
Obrigado.
Se esta resposta foi útil e resolveu ou esclareceu seu problema, por favor, marque o tópico como solucionado e clique no joia para oferecer um KUDO como agradecimento.