Pergunta
Responder
 
dcr Estudante com Louvor
Estudante com Louvor
Mensagens: 2
Membro desde: ‎24-10-2014
Mensagem 1 de 2 (1.131 Exibições)

Trocar a HD em RAID - HP PROLIANT DL 380 G6

Boa tarde!

 

Tenho um HP DL 380 G6 onde foi configurado 2 HD's em RAID 1. Uma das HD's deram problema e será substituida.

 

Minha duvida é em relação a substituição.... é só colocar a HD nova e reiniciar o servidor? Ou preciso entrar no gerenciador da controladora e fazer algum procedimento?

 

Obrigada!!

 

Daniela

 

0 Kudos
Highlighted
Mestrando
Mensagens: 324
Membro desde: ‎17-01-2013
Mensagem 2 de 2 (1.126 Exibições)

Re: Trocar a HD em RAID - HP PROLIANT DL 380 G6

[ editada ]

Ola, boa noite.

 

Como os HDs neste server são hotplug, basta trocar o HD e monitorar o rebuild através do software da controladora (Array Configuration Utility ou Smart Storage Administrator). Se vc não tiver segue link para download:

 

Para todas as versões de Windows x64

http://ftp.hp.com/pub/softlib2/software1/sc-windows/p1308213277/v87168/cp020336.exe

 

Para todas as versões de Windows x86 (32 Bit)

http://ftp.hp.com/pub/softlib2/software1/sc-windows/p640080033/v80009/cp018120.exe

 

Não é preciso reiniciar o servidor para iniciar o rebuild este processo é automatizado na controladora, quando isso estiver ocorrendo os 2 HDs ficarm com os leds piscando.

 

Segue combinações:

 

SAS/SATA hard drive LED combinations:Online/activity LED (green)Fault/UID LED (amber/blue)Interpretation

On, off, or flashing
Alternating amber and blue
The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.
On, off, or flashing
Steadily blue
The drive is operating normally, and it has been selected by a management application.
On
Amber, flashing regularly (1 Hz)
A predictive failure alert has been received for this drive. Replace the drive as soon as possible.
On
Off
The drive is online, but it is not active currently.
Flashing regularly (1 Hz)
Amber, flashing regularly (1 Hz)
Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete.
Flashing regularly (1 Hz)
Off
Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration.
Flashing irregularly
Amber, flashing regularly (1 Hz)
The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.
Flashing irregularly
Off
The drive is active, and it is operating normally.
Off
Steadily amber
A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.
Off
Amber, flashing regularly (1 Hz)
A predictive failure alert has been received for this drive. Replace the drive as soon as possible.
Off
Off
The drive is offline, a spare, or not configured as part of an array.

 

 

Qualquer duvida nos procure e caso ficou tudo OK com as dicas que passei por favor marque este post como solucionado para ajudar nossos futuros colegas.

 

Obrigado.


Se esta resposta foi útil e resolveu ou esclareceu seu problema, por favor, marque o tópico como solucionado e clique no joia para oferecer um KUDO como agradecimento.
† As opiniões expressas acima são de responsabilidade exclusiva de seus autores, e não da HP. Utilizar este site significa aceitar os termos de uso e as Regras de Participação